Close menu

Flammability tests for electrical applications

Back

When using electrical appliances and equipment, the possibility of damage, which is often associated with the development of heat or sparks, can never be completely ruled out.

Various organizations, such as the VDE or UL, have developed different test methods for assessing the fire risk of individual plastics.

The glow wire test in accordance with DIN EN 60695-2-10 ff. simulates the danger posed by heating electrical conductors.

The following are tested:

  • GWEPT - Flammability of finished products (DIN EN 60695-2-11)
  • GWFI - Flammability of materials (DIN EN 60695-2-12)
  • GWIT - Flammability of materials (DIN EN 60695-2-13)
  • GWT - general requirements for electrical appliances

When using electrical appliances and equipment, damage can be caused by the conductive effect of salty water on plastic surfaces.

The CTI or PTI value provides information on the risk of leakage currents forming under the influence of a dripped electrolyte.

One requirement for plastic components for electrical applications is sufficient heat resistance.

The test is carried out using a special test apparatus in accordance with DIN EN 60695-10-2. The specifications are contained in DIN EN 60335-1 on the safety of electrical appliances for household use, among others.

The UL 94 standard is used to classify the flammability of plastics under identical conditions.

OMPG has the equipment and experience to test materials according to the following standards:

  • UL94-V (vertical)
  • UL94-HB (horizontal)
  • UL94-HBF (for foams)
  • UL94- VTM (for foils 250 - 25µm)

Injection molding of UL rods (125mm x 13mm) is possible in the wall thicknesses: 0.8; 1.2; 1.6 and 3.0 mm.

Show test standards

Here you will find a list of all test standards for which we offer services in this area. All currently accredited standards can be found on the Accreditation page in our list of services.

Show test standards for Flammability tests for electrical applications
Back
Share
Full text search Find test standards
show test standards
close
List of test standards for Flammability tests for electrical applications
DIN EN 60112 (IEC 60112)

Method for the determination of the proof and the comparative indices solid insulating materials (VDE)

DIN EN 60695-10-2 (VDE 0471-10-2)

Fire hazard testing – Part 10–2: Abmormall heat – Ball pressure test medthod

DIN EN 60695-11-10 (VDE 0471-11-10)

Fire hazard testing – Part 11–10: Test flames – 50 W horizontal and vertical flame test method (IEC 60695-11-10)

DIN EN 60695-2-10

Fire hazard testing – Part 2–10: Glowing/hot-wire based test methods – Glow-wire apparatus and common test procedure

DIN EN 60695-2-11

Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products (GWEPT)

DIN EN 60695-2-12

Fire hazard testing – Part 2–12: Glowing/hot-wire based test methods – Glow-wire flammability index (GWFI) test method for materials

DIN EN 60695-2-13

Fire hazard testing – Part 2–13: Glowing/hot-wire based test methods – Glow-wire ignition temperature (GWIT) test method for material

IEC 60335-1 (VDE 0700-1)

Household and similar electrical appliances – Safety – T1 General requirements (GWT)

UL 94